The total dynamic head (TDH) is the height to which a pump must lift water, including head losses and pressure at the tap. It is the reference value for choosing a submersible pump from its performance curve.

The TDH formula

TDH = Hr + Pc + Pr
TermMeaning
HrStatic head: height between the water level and the point of use.
PcHead losses in the discharge pipework and friction points.
PrResidual pressure (in mWC): the pressure that must be available at the taps or for watering.

Unit: all values are expressed in metres of water column (mWC). Reminder: 1 bar = 10 mWC (see Determining water pressure).

Example calculation for a borehole pump

Installation intended to supply running water to a home of 4 people and a garden of 800 m².

TDH calculation for the example
TermDataValue
HrPump submerged at 60 m: depth between the pump intake and the borehole head, at ground level.60 mWC
PcHead losses and friction in the pipework.10 mWC
PrResidual pressure at the tap of 3.5 bar.35 mWC
TDH60 + 10 + 35105 mWC

Result

You need to choose a pump that delivers 3 m³/h at 105 m (1.50 kW or 2.20 kW depending on the pump’s flow curve). The flow rate of 3 m³/h is given by the indicative flow rate / pressure table.

Choosing the pump from the TDH

  1. Calculate the TDH (Hr + Pc + Pr), all values in mWC.
  2. Determine the required flow rate (indicative table, number of water points, watering).
  3. Read the pump curve: it must pass through the “flow rate / TDH” point of your installation.
  4. Check the motor power and the pump diameter against that of the borehole.

Common mistakes to avoid

  • Forgetting the head losses (Pc) in the discharge pipework.
  • Mixing units: adding bar and metres. Everything must be converted to mWC.
  • Not adding the residual pressure (Pr) you need at the tap or for watering.

Going further