Operation without a probe, by measuring the power factor (cos phi). Control and shutdown of the pump in the event of: lack of air in the tank, overvoltage, undervoltage, overload, lack of water. 2 x 16 character front control display, 6-button keypad to set up and control the device, four languages in the menu.
PFC-M control panel with capacitor specifications:
- Thermoplastic enclosure: 220x110x210 mm.
- Degree of protection: IP 55.
- Single-phase power supply 220-240V 50/60 Hz.
- Output power from 0.25 to 2.20 kw (max).
- Adjustment from 1 to 18 A.
- Built-in capacitor (see table below).
- Dry-running protection (cos phi measurement).
- Ambient temperature -5 +40 °C.
- Relative humidity: from 20 to 90 % non-condensing.
- The pump can operate automatically with a pressure switch (booster circuit) or a float switch (tank filling).
- Alarm output.
- Supplied with a cable of: 1.5m + a plug.
- Design in accordance with: IEC/EN 60439-1.
| Reference | Model | Voltage (V) | Power (Kw) | Capacitor | Dimensions (mm) |
|---|---|---|---|---|---|
| 008022 | PFC-M 18-16 | 230 | 0.37 | 16µF | 220x110x210 |
| 008023 | PFC-M 18-20 | 0.55 | 20µF | ||
| 008024 | PFC-M 18-25 | 25µF | |||
| 008025 | PFC-M 18-30 | 0.75 | 30µF | ||
| 008026 | PFC-M 18-35 | 35µF | |||
| 008027 | PFC-M 18-40 | 1.10 | 40µF | ||
| 008028 | PFC-M 18-50 | 1.50 | 50µF | ||
| 008029 | PFC-M 18-60 | 60µF | |||
| 008030 | PFC-M 18-70 | 2.20 Kw | 70µF |
Operation and alarms:
- Automatic pump operation.
- Undervoltage and overvoltage: visual warning and pump stop.
- Motor overload: visual warning and pump stop.
- Lack of water: visual warning and pump stop.
- Lack of air in bladder pressure tank: pump stops after 4 restarts.
Options:
- RA 100 alarm panel, fitted with a buzzer and a flashing red light: ref 008031.